SCSI 50-Conductor Quiet

It appears that you are using AdBlocking software. The cost of running this website is covered by advertisements. If you like it please feel free to a small amount of money to secure the future of this website.

Image:conn_50p_cable.gif Cable Pair Location

PIN CABLE PAIR SINGLE ENDED Signal Name DIFFERENTIAL Signal Name
1 13 GROUND GROUND
2 14 GROUND +DB0
3 15 GROUND +DB1
4 16 GROUND +DB2
5 17 GROUND +DB3
6 18 GROUND +DB4
7 19 GROUND +DB5
8 20 GROUND +DB6
9 21 GROUND +DB7
10 22 GROUND +PARITY
11 23 GROUND DIFFSENSE
12 24 RESERVED RESERVED
13 25 OPEN TERMPWR
14 11 RESERVED RESERVED
15 12 GROUND +ATN
16 3 GROUND GROUND
17 4 GROUND +BSY
18 5 GROUND +ACK
19 2 GROUND +RST
20 6 GROUND +MSG
21 7 GROUND +SEL
22 8 GROUND +C/D
23 9 GROUND +REQ
24 1 GROUND +I/O
25 10 GROUND GROUND
26 13 -DB0 GROUND
27 14 -DB1 -DB0
28 15 -DB2 -DB1
29 16 -DB3 -DB2
30 17 -DB4 -DB3
31 18 -DB5 -DB4
32 19 -DB6 -DB5
33 20 -DB7 -DB6
34 21 -PARITY -DB7
35 22 GROUND -PARITY
36 23 GROUND GROUND
37 24 RESERVED RESERVED
38 25 TERMPWR TERMPWR
39 11 RESERVED RESERVED
40 12 GROUND -ATN
41 3 -ATN GROUND
42 4 GROUND -BSY
43 5 -BSY -ACK
44 2 -ACK -RST
45 6 -RST -MSG
46 7 -MSG -SEL
47 8 -SEL -C/D
48 9 -C/D -REQ
49 1 -REQ -I/O
50 10 -I/O GROUND